LED-integrated-tube-light-283x187

Features

 

  • Input voltage: AC90-277V
  • Operating frequency: 50/60Hz
  • Power factor: 0.90
  • Ambient temperature range: -20°C ~+40°C
  • Color Temp: 3000K~5000K
  • THD: <20%
  • IP Rating: IP20
  • CRI: >80Ra
  • Beam angle: 120°
  • Base: G13
  • Cover:Clear,Frosted,Stripe
  • Luminous Flux:>120lm/w
  • Housing material:6063-T5
  • Suitable for Damp Location
  • Suitable to use in UL approved enclosed fixtures
  • Available for Single Ended Power or Double Ended Power
  • 5 years’ warranty

 

Mounting Guides

LED-integrated-tube-light01
led-cooler-light-mounting-img2

Electric Shock Attention

Ensure the power supply has been cut off before connecting the wire, and all wiring and installation of this product are required to be operated by professionals.

Installation Instruction

Step1: Place Clip Kits and Screws Correctly
LED-integrated-tube-light03
Step2: Fix the LEd Tube to the Ceiling or Wall
LED-integrated-tube-light04
Step3: Connect the Power Cord to the Tube
LED-integrated-tube-light05
Step4: Connect by Linkable Connector
LED-integrated-tube-light06

Caution: The integrated tubes can not be connected more than total pcs

LED-integrated-tube-light07

For model zs-t8y0610 and ses-t8y1222, the max connecting quantity of tube is ≤8 pcs.
For model zs-t8y2445, the max connecting quantity of tube is ≤5 pcs.
For model zs-t8y2460, when using rated 125v/10a power supply wire, the max connecting quantity of tube is
≤5 pcs. When using rated 250v/2.5a power supply wire, the max connecting quantity of tube is ≤3 pcs

LED-integrated-tube-light dimention

Notice For User

1. Disconnect power before installation, must operated by electrician
2. Take out the tube. Before installation please check if there is any unsatisfactory condition of the tube,
Such as whether the appearance is damaged or deformed, or the accessories are complete or not.
3. Please use it under correct input power range
4. This tube is non-dimmable
5. Not for outdoor or some where be exposed to rain(waterproof type available)
6. If the lights don’t work properly, please check the connections after turning off the power
7. Use ul approved 3-pin plug.